Q0009 - Reinstatement of SMA and Thin Surfacings

Date Submitted: Monday, 12th December 2005

Question:

Reinstatement of SMA and thin surfacings?

Answer:

Whilst SMA PCMs were not anticipated under SROHv2 (June 2002), they should not be precluded just because a manufacturer had gone through the BBA/HAPAS approvl process as such it is considered satisfactory that SMA PCSMs can be used in both SMA and thin surfacing applications in 2s, 3s and 4s roads.